Membrane
1. Characteristics
  • Sophisticated spinning technology for good permeability
  • The membrane material, Polysulfone has superior chemical resistance and chemical resistance.
  • Our filter can reject harmful suspended materials and bacteria and permeate healthful mineral.
2. Specification

( *) Refer to 3.1 , (**) Refer to 3.2 , (***) Refer to 3.3.

3. Test method and result

3.1. Filter-out particles

    • Standard particle : Polystyrene latex bead(Sigma, mean dia.: 0.03, 0.05 μm)
    • Pressure : 1 kgf/cm²
    • Analysis : UV Spectrometer(λ=320 nm)
    • Influent : 100 ppm aqueous suspension
    • Effluent: 7.5 ppm for 0.03 μm (92.5 % rejected)
      -1.5 ppm for 0.05 μm (98.5 % rejected)
img_05

3.2. Permeability data

3.3. Bacteria removal test

    • Specimen : E. Coli, S. aureus
    • Water-in : 710 CFU/ml(E. Coli), 550 CFU/ml(S. aureus)
    • Analysis : UV Spectrometer(λ=320 nm)
    • water-out : Negative(0 CFU/ml, 100% rejected)
      - * Tested at Korea Testing & Research Institue (KOTRIC)
4. SEM Photographs

* The real effect to cut off 0.03㎛ latex beads 92.5% by the overlaying structure